Magnetic Resonance Imaging (MRI) I
  • Magnetic Resonance Imaging (MRI) I

Magnetic Resonance Imaging (MRI) I

공유
모델명
P5942400
브랜드
PHYWE
판매가
견적 문의
배송비
₩2,500 / 주문시결제(선결제) 조건별배송
택배
방문 수령지 : 경기도 고양시 덕양구 향동로 194(향동동) DMC아미 지식산업센터 501호

 

Features
Principle
The basic principles of 2D MR imaging are demonstrated with two methods relying on two different gradient techniques. Experiments are executed with a MRT training device giving the opportunity to investigate some small probes in the sample chamber. Device control is done with the provided software. Investigations comprise the generation of a two-dimensional cross-section image via the spin echo technique, i.e. a spin echo signal is investigated while simultaneously superimposed with a magnetic field gradient, and the generation of a two-dimensional cross-section image via the gradient echo technique, i.e. a particular gradient echo signal is investigated. The latter technique is closely linked to the FLASH (Fast Low Angle Shot) which is an ultrafast technique in MR imaging. 
Benefits
Complete, easy to install and affordable MRT education system
One system to cover all aspects from NMR basics to sophisticated 2D and 3D imaging sequences
Detailed experiment guides included with the system
Learning results guaranteed thanks to easy to manage course steps
Can be set up at any location in the student lab
Experience the realistic sound of the different MR sequences
Tasks
1. Using the frequency and phase gradient techniques to generate a spin echo signal which can be used for 2D image reconstruction (Spin Echo 2D).
2. Using the frequency and phase gradient techniques to generate a gradient echo signal which can be used for 2D image reconstruction (Flash 2D).
What you can learn about
Nuclear spins
Precession of nuclear spins
Resonance condition, MR frequency
MR flip angle
FID signal (Free Induction Decay)
Magnetic gradient fields
Spatial encoding (frequency coding, phase coding)
Spin echo, gradient echo
Fast-Fourier-Transformation (FFT)
T1/T2 relaxation times 
De-/Rephasing

 

 

 

 

Descripsion Code Q'ty
PHYWE Compact magnetic resonance tomograph (MRT) 09500-99 1,00

 

 

 

배송안내

- 배송비 : 기본배송료는 2,500원 입니다. (도서,산간,오지 일부지역은 배송비가 추가될 수 있습니다)  100,000원 이상 구매시 무료배송입니다.

- 본 상품의 평균 배송일은 2일입니다. 설치 상품의 경우 다소 늦어질수 있습니다.

교환 및 반품안내

- 개봉으로 상품 가치 훼손 시에는 상품수령후 7일 이내라도 교환 및 반품이 불가능합니다.

- 저단가 상품, 일부 특가 상품은 고객 변심에 의한 교환, 반품은 고객께서 배송비를 부담하셔야 합니다(제품의 하자,배송오류는 제외)

- 일부 상품은 신모델 출시, 부품가격 변동 등 제조사 사정으로 가격이 변동될 수 있습니다.

환불안내

- 상품 청약철회 가능기간은 상품 수령일로 부터 7일 이내 입니다.

AS안내

- 소비자분쟁해결 기준(공정거래위원회 고시)에 따라 피해를 보상받을 수 있습니다.

- A/S는 판매자에게 문의하시기 바랍니다.

이미지 확대보기Magnetic Resonance Imaging (MRI) I

Magnetic Resonance Imaging (MRI) I
  • Magnetic Resonance Imaging (MRI) I
닫기

비밀번호 인증

글 작성시 설정한 비밀번호를 입력해 주세요.

닫기

장바구니 담기

상품이 장바구니에 담겼습니다.
바로 확인하시겠습니까?

찜 리스트 담기

상품이 찜 리스트에 담겼습니다.
바로 확인하시겠습니까?