Debye-Scherrer diffraction measurements for the examination of the texture of rolled sheets
  • Debye-Scherrer diffraction measurements for the examination of the texture of rolled sheets

Debye-Scherrer diffraction measurements for the examination of the texture of rolled sheets

공유
모델명
P2542701
브랜드
PHYWE
판매가
견적 문의
배송비
₩2,500 / 주문시결제(선결제) 조건별배송
택배
방문 수령지 : 경기도 고양시 덕양구 향동로 194(향동동) DMC아미 지식산업센터 501호

 

Features
Principle
A polycrystalline, cubic face-centered crystallizing copper powder sample and a thin copper sheet are separately irradiated with the radiation from a Roentgen tube with a copper anode. A Geiger-Mueller counter tube is automatically swivelled to detect the radiation that is constructively reflected from the various lattice planes of the crystallites. The Bragg diagrams are automatically recorded. The evaluation allows the Bragg reflexes to be assigned to the individual lattice planes. In contrast to the powder sample, the rolled thin sheet gives a spectrum showing an alignment of the crystallites (rolled texture), that is made even more complete by heating the sheet.
Tasks
1. Record the intensity of the Cu X-rays back scattered by a cubic crystallizing copper powder sample as a function of the scattering angle.
2. Assign the Bragg reflexes to the individual lattice planes.
3. Record the Bragg spectrum of a thin sheet of copper.
4. Repeat the measurements made in Task 3 after the sheet of copper has been subjected to annealing.
What you can learn about
Crystal lattices
Crystal systems
Bravais-lattice
Reciprocal lattice
Miller indices
Structure factor
Atomic scattering factor
Bragg scattering
Characteristic X-rays
Monochromatization of X-rays
Fiber textures
Sheet textures
Annealing texture
Recrystallization

 

 

 

 

Descripsion Code Q'ty
XR 4.0 X-ray sample holder for powder samples (diffractometry) 09058-09 1,00
Geiger-Mueller counter tube, type B, BNC cable 50 cm 09005-00 1,00
Copper, powder 100 30119-10 1,00
XR 4.0 X-ray goniometer 09057-10 1,00
XR 4.0 X-ray Plug-in Cu tube 09057-51 1,00
XR 4.0 Software measure X-ray 14414-61 1,00
XR 4.0 X-ray Diaphragm tube w. nickel foil 09056-03 1,00
Vaseline 100 30238-10 1,00
XR 4.0 expert unit, 35 kV 09057-99 1,00
Data cable USB, plug type A/B, 1.8 m 14608-00 1,00
XR 4.0 X-ray LiF crystal, mounted 09056-05 1,00
Microspoon, steel 33393-00 1,00
XR 4.0 X-ray Universal crystal holder for X-ray unit 09058-02 1,00
Copper foil, 0.1 mm, 100 30117-10 1,00
Crucible tongs, 200 mm, stainless steel 33600-00 1,00
XR 4.0 X-ray Diaphragm tube d = 2 mm 09057-02 1,00

 

 

배송안내

- 배송비 : 기본배송료는 2,500원 입니다. (도서,산간,오지 일부지역은 배송비가 추가될 수 있습니다)  100,000원 이상 구매시 무료배송입니다.

- 본 상품의 평균 배송일은 2일입니다. 설치 상품의 경우 다소 늦어질수 있습니다.

교환 및 반품안내

- 개봉으로 상품 가치 훼손 시에는 상품수령후 7일 이내라도 교환 및 반품이 불가능합니다.

- 저단가 상품, 일부 특가 상품은 고객 변심에 의한 교환, 반품은 고객께서 배송비를 부담하셔야 합니다(제품의 하자,배송오류는 제외)

- 일부 상품은 신모델 출시, 부품가격 변동 등 제조사 사정으로 가격이 변동될 수 있습니다.

환불안내

- 상품 청약철회 가능기간은 상품 수령일로 부터 7일 이내 입니다.

AS안내

- 소비자분쟁해결 기준(공정거래위원회 고시)에 따라 피해를 보상받을 수 있습니다.

- A/S는 판매자에게 문의하시기 바랍니다.

이미지 확대보기Debye-Scherrer diffraction measurements for the examination of the texture of rolled sheets