Features
Principle
Dosimetry, as a subspecialty of medical physics, deals with the determination and calculation of dose rates, which is also of great importance in view of the radiation protection directives. This experiment demonstrates the principle of measurement and it explains the various units of absorbed dose, equivalent dose, and absorbed dose rate. Inside a plate capacitor, an air volume is irradiated with X-rays. The resulting ion current is used to determine the dosimetric data.
Tasks
1. Using the two different diaphragm tubes and the fluorescent screen, the given distance between the aperture and the radiation source at maximum anode voltage and current is to be determined.
2. The ion current at maximum anode voltage is to be measured and graphically recorded as a function of the capacitor voltage by using two different beam limiting apertures. The ion dose rate and the energy dose rate are to be determined from the saturation current values.
3. Using the d = 5 mm aperture, the ion current is to be determined and graphically recorded at various anode currents but with maximum anode and capacitor voltages.
4. The ion current is to be measured and graphically recorded as a function of the capacitor voltage at different anode voltages and the corresponding saturation currents plotted graphically.
What you can learn about
X-rays
Absorption inverse square law
Ionizing energy
Energy dose
Equivalent dose and ion dose and their rates
Q factor
Local ion dose rate
Dosimeter

 

 

 

 

Descripsion Code Q'ty
Slide mount for optical bench expert 08286-00 1,00
Digital Multimeter, 2.000 Counts, 600V AC/DC, 10A, with NiCr-Ni thermocouple and inductance measurement 07129-00 1,00
XR 4.0 X-ray Diaphragm tube d = 2 mm 09057-02 1,00
Adaptor, BNC socket/4 mm plug 07542-20 1,00
Screened cable, BNC, l 250 mm 07542-10 1,00
Connecting cord, 32 A, 750 mm, red 07362-01 1,00
Connecting cord, 32 A, 500 mm, blue 07361-04 1,00
Connecting cord, 32 A, 500 mm, red 07361-01 1,00
Connecting cord, 32 A, 250 mm, blue 07360-04 1,00
Connecting cord, 32 A, 250 mm, red 07360-01 1,00
Connecting cord, 32 A, 100 mm, blue 07359-04 1,00
High-value resistor, 50 megOhms 07159-00 1,00
XR 4.0 X-ray plug-in W tube 09057-81 1,00
PHYWE power supply, regulated DC: 0...12 V, 0,5 A; 0...650 V, 50 mA / AC: 6,3 V, 2 A 13672-93 1,00
PHYWE Universal measuring amplifier 13626-93 1,00
XR 4.0 X-ray Capacitor plates f.x-ray-unit 09058-05 1,00
XR 4.0 expert unit, 35 kV 09057-99 1,00
XR 4.0 X-ray fluorescent screen 09057-26 1,00
XR 4.0 X-ray optical bench 09057-18 1,00
XR 4.0 X-ray holder for capacitor plates 09057-05 1,00
XR 4.0 X-ray Diaphragm tube d = 5 mm 09057-03 1,00

 

 

배송안내

- 배송비 : 기본배송료는 2,500원 입니다. (도서,산간,오지 일부지역은 배송비가 추가될 수 있습니다)  100,000원 이상 구매시 무료배송입니다.

- 본 상품의 평균 배송일은 2일입니다. 설치 상품의 경우 다소 늦어질수 있습니다.

교환 및 반품안내

- 개봉으로 상품 가치 훼손 시에는 상품수령후 7일 이내라도 교환 및 반품이 불가능합니다.

- 저단가 상품, 일부 특가 상품은 고객 변심에 의한 교환, 반품은 고객께서 배송비를 부담하셔야 합니다(제품의 하자,배송오류는 제외)

- 일부 상품은 신모델 출시, 부품가격 변동 등 제조사 사정으로 가격이 변동될 수 있습니다.

환불안내

- 상품 청약철회 가능기간은 상품 수령일로 부터 7일 이내 입니다.

AS안내

- 소비자분쟁해결 기준(공정거래위원회 고시)에 따라 피해를 보상받을 수 있습니다.

- A/S는 판매자에게 문의하시기 바랍니다.

이미지 확대보기X-ray dosimetry

X-ray dosimetry
  • X-ray dosimetry
닫기

비밀번호 인증

글 작성시 설정한 비밀번호를 입력해 주세요.

닫기

장바구니 담기

상품이 장바구니에 담겼습니다.
바로 확인하시겠습니까?

찜 리스트 담기

상품이 찜 리스트에 담겼습니다.
바로 확인하시겠습니까?